CPF2694 - Object &2 type *&5 cannot be renamed. ( OS/400 )
General Material Data Vendor Master (General Section)This documentation is copyright by IBM.
Message : CPF2694
Object &2 type *&5 cannot be renamed.
Message Long Text :
Cause . . . . . : Object &2 type *&5 cannot be renamed at this time. The reason code is: &3. Reason codes and their meanings follow:
1001 - Connection lists cannot be renamed while there are active references to the connection list.
1002 - Workstation controller cannot be renamed while the associated TDLC line is varied on.
1003 - Workstation controller descriptions cannot be renamed by a user without the authority to change the associated line description.
1004 - APPC controller descriptions cannot be renamed if the control owner (CTLOWN parameter) is the system (*SYS).
1005 - TDLC line description cannot be renamed while the associated controllers are varied on.
1006 - TDLC line description cannot be renamed by a user without authority to change the associated controller descriptions.
1007 - The system resource manager database could not be updated with the new name for an automatically configured controller description.
Recovery . . . : Reason codes and recoveries. Do one of the following, then try the request again:
1001 - Use the VRYCFG command to vary off any line or controller descriptions that reference the connection list.
1002 - Use the VRYCFG command to vary off the line description associated with the work station controller.
1003 - Use the edit authorities option on the Work with Objects (WRKOBJ) display to change authority to the TDLC line description.
1004 - Use the CHGCTLAPPC command to change the control owner (CTLOWN parameter) to *USER.
1005 - Use the VRYCFG command to vary off the controllers associated with this TDLC line description.
1006 - Use the edit authorities option on the Work with Objects (WRKOBJ) display to change authority to the work station controllers.
1007 - See previously listed errors in the job log.
Message File : QCPFMSG
Library Message File : QSYS2924
Fill RESBD Structure from EBP Component Structure BAL Application Log Documentation