Ansicht
Dokumentation
CPF33DA - Value &1 not valid for number of buffers to read parameter. ( OS/400 )
CPI1466 during Backup CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : CPF33DA
Value &1 not valid for number of buffers to read parameter.
Message Long Text :
Cause . . . . . : The value specified for the number of buffers to read parameter of an Application Program Interface (API) is not valid. The number of buffers to read parameter must have a value of 1 through 8; 16, 24, or 32. If the value is greater than 32, it must be a multiple of 32. For example 64, 96 and so forth. A special value of -1 is also allowed.
Recovery . . . : Specify an allowed value for the number of buffers to read parameter of the API and try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
ROGBILLS - Synchronize billing plans CPI1466 during Backup
This documentation is copyright by IBM.
Length: 3241 Date: 20240426 Time: 190316 sap01-206 ( 3 ms )