CPF427B - Input/output mapping cannot be performed. CCSID values not compatible. ( OS/400 )
PERFORM Short Reference Addresses (Business Address Services)This documentation is copyright by IBM.
Message : CPF427B
Input/output mapping cannot be performed. CCSID values not compatible.
Message Long Text :
Cause . . . . . : Field &1 with CCSID (Coded Character Set Identifier) &3 in format &2, specified as an I/O (input/output) field, cannot be converted to CCSID &4, the final CCSID required for the I/O field. Either the CCSID of the field is not compatible with the final CCSID, or double-byte conversion, which is not supported for fields, is required.
Recovery . . . : Either change the final CCSID &4 (using the CHGJOB command, if it is the job's CCSID) to be a CCSID compatible with CCSID &3 or specify a different I/O field than &1 that has a CCSID compatible with CCSID &4. Try your request again after this change. See the i5/OS globalization topic collection in the Programming category in the IBM i Information Center, http://www.ibm.com/systems/i/infocenter/, for more details on CCSIDs.
Message File : QCPFMSG
Library Message File : QSYS2924
TXBHW - Original Tax Base Amount in Local Currency ABAP Short Reference
This documentation is copyright by IBM.
Length: 3252 Date: 20240426 Time: 234540 sap01-206 ( 3 ms )