CPF8105 - Device description &4 damaged. ( OS/400 )

CPF8105 - Device description &4 damaged. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF8105
Device description &4 damaged.

Message Long Text :

Cause . . . . . : Device description &4 has &8 damage and may no longer be usable. The VLOG dump identifier is &7.
Recovery . . . : If full damage occurred, delete the device description (DLTDEVD command), and do one of the following:
-- Create the device description again with the appropriate create device command.
-- Restore the configuration (RSTCFG command) from the save tape. The configuration must be restored from a tape that was saved using the Save System (SAVSYS) or Save Configuration (SAVCFG) commands.
-- Restore the command source for the device description. The command source must have been saved using a previous Retrieve Configuration Source (RTVCFGSRC) command.
Any associated controller descriptions may need to be deleted and created again. If the damaged device description is the console, the system may need to be powered down (PWRDWNSYS command). If the system is powered down, do an initial program load (IPL) of the system.
If partial damage occurred, vary off the device and vary the device on (VRYCFG command) again. The system may need to be powered down (PWRDWNSYS command) to vary off the device. If the system is powered down, do an initial program load (IPL) of the system. If partial damage is indicated on a 9347 Tape Unit, determine if it was processing a 3600 foot tape. A 9347 Tape Unit can only process up to 2400 foot tapes.