Message : CPF813B
Object containing SNADS internal queues damaged.

Message Long Text :

Cause . . . . . : The object containing the SNADS internal queues was found damaged and was deleted. The VLOG log dump identifier is &6.
Recovery . . . : To create the object containing the SNADS internal queues and restore its entries do the following:
1 - If the QSNADS subsystem is active, end the subsystem by running ENDSBS QSNADS.
2 - Start the QSNADS subsystem by running STRSBS QSNADS.
Technical description . . . . . . . . : The SNADS functions on this system will not work without the object containing the SNADS internal queues. Starting the subsystem again will create this object and restore all the SNADS queues entries.

Message File : QCPFMSG
Library Message File : QSYS2924