CPF87DB - STRTCPTELN not allowed in pass-through environment. ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : CPF87DB
STRTCPTELN not allowed in pass-through environment.
Message Long Text :
Cause . . . . . : Starting a TELNET environment is not allowed while you are in certain 5250 display station pass-through environments. These environments are source pass-through and target pass-through which originated at a Version 2 Release 2 Modification 0 or earlier system.
Recovery . . . : Do one of the following and then enter the Start TCP TELNET (STRTCPTELN) command:
-- End the current pass-through session
-- Request the System Request menu using the system request key, select option 10 from the System Request menu, and then sign on to an alternate job.