Ansicht
Dokumentation

CPFB51A - Start Job Watcher did not complete successfully. ( OS/400 )

CPFB51A - Start Job Watcher did not complete successfully. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPFB51A
Start Job Watcher did not complete successfully.

Message Long Text :

Cause . . . . . : The Start Job Watcher (STRJW) command encountered an error and did not complete successfully. Reason code is &1. The following reason codes indicate why the STRJW command did not complete successfully:
1 - Definition not found.
2 - Collection could not start due to invalid data selection criteria.
3 - Collection could not start due to invalid thread selection criteria.
4 - Collection could not start due to invalid condition selection criteria.
5 - Error encountered on call to user exit program.
Recovery . . . : Correct the values on the STRJW command and try the command again. Job Watcher definitions may be created using the Add Job Watcher Definition (ADDJWDFN) command.

Message File : QCPFMSG
Library Message File : QSYS2924


Addresses (Business Address Services)   General Material Data  
This documentation is copyright by IBM.

Length: 3240 Date: 20240427 Time: 015130     sap01-206 ( 3 ms )