Ansicht
Dokumentation

CPFE03C - DFTMAXDTG parameter value &1 not valid for IPX circuit &3. ( OS/400 )

CPFE03C - DFTMAXDTG parameter value &1 not valid for IPX circuit &3. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   ABAP Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPFE03C
DFTMAXDTG parameter value &1 not valid for IPX circuit &3.

Message Long Text :

Cause . . . . . : The Default Maximum Datagram size (DFTMAXDTG) parameter value &1 for IPX circuit &3 is greater than the maximum frame size on line description &2.
Recovery . . . : Do one of the following and then try the request again:
-- Use the Change IPX Circuit (CHGIPXCCT) CL command to change the DFTMAXDTG parameter value to a value that is less than the maximum frame size for line description &2.
-- Use the CHGLINxxx (where xxx is equal to the type of line being changed) CL command to change the maximum frame size for line description &2 to a value that is greater than or equal to the DFTMAXDTG parameter value &1.
-- Use the Add IPX Circuit (ADDIPXCCT) CL command and set the DFTMAXDTG parameter value to a value that is less than the maximum frame size for line description &2.

Message File : QCPFMSG
Library Message File : QSYS2924


ABAP Short Reference   ABAP Short Reference  
This documentation is copyright by IBM.

Length: 3246 Date: 20240426 Time: 191557     sap01-206 ( 2 ms )