Ansicht
Dokumentation

CPI5944 - Call from controller on IDLC line &23 rejected. ( OS/400 )

CPI5944 - Call from controller on IDLC line &23 rejected. ( OS/400 )

CPI1466 during Backup   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI5944
Call from controller on IDLC line &23 rejected.

Message Long Text :

Cause . . . . . : A remote system with data link control identifier (DLCI) &43, remote network identifier (RMTNETID) &40, remote control point name (RMTCPNAME) &41, exchange identifier (EXCHID) &42, system service control point identifier (SSCPID) &44, and adjacent link station name (ADJLNKSTN) &45 tried to establish an IDLC connection with this system. No varied on controller has matching parameters.
Recovery . . . : Verify that the proper controllers are varied on and configured correctly.
For APPC controllers, the following must be true for call acceptance:
- an APPC controller is vary on pending
- the received DLCI equals 256
- RMTNETID and RMTCPNAME, EXCHID, or all were received
- if the values RMTNETID and RMTCPNAME or EXCHID were configured in the controller description intended for the call, they must match the compatible values received from the adjacent system. If neither value was configured or received, check other parameters.
- at least one of the above parameters must match to find the controller description. If certain values are not configured or received, a configuration change may be needed.
For HOST controllers, the following must be true for call acceptance:
- a HOST controller is vary on pending
- the received DLCI equals 256
- the values RMTNETID and RMTCPNAME, SSCPID, ADJLNKSTN or all were received
- if the values RMTNETID and RMTCPNAME, EXCHID or ADJLNKSTN were configured in the controller description intended for the call, they must match the compatible values received from the adjacent system. If neither value was configured or received, check other parameters.
- at least one of the above parameters must match to find the controller description. If certain values are not configured or received, a configuration change may be needed.
For remote work station controllers, the following must be true for call acceptance:
- a remote work station controller is vary on pending
- the received DLCI equals 256
- the received EXCHID matches the EXCHID in the controller description.
Have the remote system operator try the request again.
If the problem continues, report the problem (ANZPRB command).

Message File : QCPFMSG
Library Message File : QSYS2924


RFUMSV00 - Advance Return for Tax on Sales/Purchases   RFUMSV00 - Advance Return for Tax on Sales/Purchases  
This documentation is copyright by IBM.

Length: 3265 Date: 20240426 Time: 062510     sap01-206 ( 3 ms )