CPI5DA2 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

CPI5DA2 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI5DA2
CP-SVR pipe to DLUS &3.&4 on controller &7 not established.

Message Long Text :

Cause . . . . . :
The Dependent Logical Unit Server (DLUS) &3.&4 sent Systems Network Architecture (SNA) UNBIND request on the CP-SVR pipe.
Recovery . . . :
Contact the system operator at the DLUS. Request that the operator check for messages which might have been logged and which might help determine the problem.
The local system attempts to establish a CP-SVR pipe to the DLUS &3.&4 if the DLUR controller is configured to retry connections (CMNRCYLMT parameter).
If there is a backup DLUS specified (BKUDLUS parameter), the local system attempts to establish a CP-SVR pipe to the backup DLUS under the following conditions:
-- DLUS &3.&4 is the primary DLUS (PRIDLUS parameter) for controller &7 and the configured retry limits have been reached
-- DLUS &3.&4 is the primary DLUS for controller &7 and the DLUR controller is not configured to retry the connection
If the configured retry limits have been reached for the DLUR controller to the primary DLUS and backup DLUS, use the Display Messages (DSPMSG) command to check the system operator message queue (QSYSOPR) or the configured message queue. Locate message CPA5D80 or CPA5D88 for controller &7. Reply to message CPA5D80 or CPA5D88 with the retry option to retry the request.
Technical description . . . . . . . . :
The DLUS sent UNBIND of the CP-SVR pipe with sense data &1.
The SNA sense data and the problem detected follows:
1001 xxxx - A general data stream (GDS) variable was received that is incorrect.
The DLUS may have sent data which does not conform to SNA protocol.
If the high-order bit in byte 2 is set to 1, then the 15 low-order bits of bytes 2 and 3 contain the index of the first byte of the field found to be in error.
0877 0056 - The CP-SVR pipe attempted to cross a LEN connection which is not a connection into a TCP/IP network.
For information about other SNA sense data, see the SNA Formats, GA27-3136.

Message File : QCPFMSG
Library Message File : QSYS2924