CPI7E9B - Unable to establish a network link on Ethernet line &23 ( OS/400 )

CPI7E9B - Unable to establish a network link on Ethernet line &23 ( OS/400 )

ABAP Short Reference   BAL Application Log Documentation  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI7E9B
Unable to establish a network link on Ethernet line &23

Message Long Text :

Cause . . . . . : One of the following may have caused the error:
-- The Ethernet external cable.
-- The line is configured for 10M bits per second, and the network will only support 100M bits per second.
-- The line is configured for 100M bits per second, and the network will only support 10M bits per second.
-- The Ethernet adapter card.
Recovery . . . :
-- Make sure the Ethernet cable is attached to the Ethernet adapter card and a network device.
-- Check the Ethernet cable for physical damage. If the cable type is UTP (unshielded twisted pair), make sure the cable is wired according to the EIA/TIA-568A standard:
Pins 1 and 2 using the same twisted pair,
Pins 3 and 6 using the same twisted pair,
Pins 4 and 5 using the same twisted pair,
Pins 7 and 8 using the same twisted pair.
-- Verify that the line configuration matches the network's supported line speed.
-- If any cabling or configuration problems were found and corrected, reply to any unanswered messages in the QSYSOPR message queue, (vary off/on the Ethernet line if necessary), and retry the procedure that failed.
-- If no cabling/configuration problems were found, press F14 to report the problem to your hardware service provider.

Technical description . . . . . . . . :
To determine if the Ethernet adapter card is defective, perform the hardware verification test, as indicated below:
First, determine the port hardware resource name using the Display Line Description command for line &23 (DSPLIND &23 ). Once you have determined the resource name, start System Service Tools (STRSST), then select Start a service tool, Hardware Service Manager, Locate Resource by Resource name. Enter the port hardware resource name and then select the Verify option, and run all tests. If all tests pass, do not replace the adapter card.

- Line Description Name..: &23
- Processor Resource ....: &26
- Adapter Resource ......: &27

Message File : QCPFMSG
Library Message File : QSYS2924