Message : CPI7F9C
Receive CRC limit reached on line &23, attached to network interface &30.

Message Long Text :

Cause . . . . . : One of the following may have caused the problem:
-- The network may be having noise problems.
-- The local environment may be electrically noisy.
-- The wrong information transfer type is being used.
-- If a nonswitched B-channel is being used, the wrong information transfer type may not be correct.
Recovery . . . : You may choose to ignore this message because your line is operational. If you suspect line quality problems, consult your local ISDN network provider. If electrical noise is suspected, try eliminating the source. If a wrong information transfer type is suspected, you may change it using the INFTRFTYPE parameter in the CHGLINIDLC command. You may change the frequency of occurrence of this message by adjusting the value of the CRCRCV and THRESHOLD parameters, using the CHGLINIDLC command. If problem still persists, press F14 to analyze and report the problem.
Technical description . . . . . . . . : The number of cyclic redundancy check (CRC) errors that occurred during a specified time period exceeded the limit and caused this message to be displayed.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924