Ansicht
Dokumentation

CPI8E01 - Line &23 threshold information. ( OS/400 )

CPI8E01 - Line &23 threshold information. ( OS/400 )

BAL_S_LOG - Application Log: Log header data   General Data in Customer Master  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E01
Line &23 threshold information.

Message Long Text :

Cause . . . . . : One of the following may have caused the problem:
-- The local modem options for data-set-ready (DSR) may be set incorrectly.
-- The environment may be electrically noisy.
-- The modem may not be properly grounded.
-- The telephone line quality may be poor (low probability).
Recovery . . . : You may choose to ignore this message because your line is operational. If you are not satisfied with the operation of your communications equipment, verify that your modem is configured correctly for data-set-ready (DSR). Refer to the IBM Systems Hardware Information Center Planning information for information about electrical requirements and noise problem considerations. Consult the modem manufacturer to determine the proper grounding technique to use. Consult the local telephone company to have the line tested to verify line quality. The threshold function may be turned off in the threshold (THRESHOLD) parameter on the CRTLINSDLC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : The data-set-ready (DSR) signal had a line transition error many times and caused a threshold error. A line transition error is the occurrence of a single instance of a signal changing high or low and returning to its original level. Multiple instances within a short period (bouncing) are considered a single line transition error. Initial line stabilization is not considered a line transition error. If a DSR signal gets line transition errors for 20 msec on a switched line, a permanent error will be reported in addition to this message and the line will be disconnected.

- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


PERFORM Short Reference   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.