Message : CPI8E6B
Error on line &23.

Message Long Text :

Cause . . . . . : One of the following may have caused the problem:
-- Too many communications lines may be active at the same time.
-- Too many service functions may be active (for example, communications trace, input/output processor program trace).
-- Your modem speed may be set too fast.
Recovery . . . : Reduce your communications work load by turning off lines or by ending service functions that are not needed. To determine which lines are active and use the same communications controller, vary off the line and vary it on using the vary configuration (VRYCFG command) with RESET(*YES) specified. The VRYCFG command will display a message for each active line. Then vary off these lines and vary on the line in error to reset this line. If this problem continues, press F14 to run problem analysis.
Technical description . . . . . . . . : The communications controller could not process data fast enough.