CPI8E8A - Line &23 failed during insertion into the token-ring network ( OS/400 )

CPI8E8A - Line &23 failed during insertion into the token-ring network ( OS/400 )

PERFORM Short Reference   BAL Application Log Documentation  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E8A
Line &23 failed during insertion into the token-ring network

Message Long Text :

Cause . . . . . : The token-ring adapter detected a signal loss or frequency error during the insertion process into the token-ring network. The following may have caused the problem:
-- A faulty or excessively long cable in the token-ring network.
-- A poor connection between the token-ring adapter and the multiple station access unit (MSAU) or between the MSAU and the token-ring network.
-- The environment may be electrically noisy.
Recovery . . . : Press F14 to run problem analysis. This status information is returned because the token-ring adapter card has detected an absence of a receive signal or a frequency error on the token-ring network during insertion processing. If this problem persists, inspect token-ring network for poor cabling. Refer to the System Hardware Information Center Planning information for information about the electrical requirements and noise problem considerations. If possible, use a token-ring network manager to isolate the cause and source of the problem.
Technical description . . . . . . . . :

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   BAL Application Log Documentation  
This documentation is copyright by IBM.

Length: 3262 Date: 20240426 Time: 151525     sap01-206 ( 3 ms )