Ansicht
Dokumentation
CPI8ED3 - Frame received on line &23 rejected by local system. ( OS/400 )
BAL Application Log Documentation Addresses (Business Address Services)This documentation is copyright by IBM.
Message : CPI8ED3
Frame received on line &23 rejected by local system.
Message Long Text :
Cause . . . . . : This is a temporary condition; however, if your line is not operational, the probable causes are:
-- The X.25 network is not working correctly.
-- The I/O card Licensed Internal Code is not working correctly.
Recovery . . . : If line &23 is not operational, do one or more of the following:
-- Contact the X.25 network provider to verify that the X.25 network is operational.
-- If the problem continues, report the problem (ANZPRB command).
Technical description . . . . . . . . :
A high level data link control (HDLC) frame received on line &23 had a sequence number that was not correct. The local system rejected the frame in error, by transmitting an HDLC frame reject (FRMR) frame in response to a previously received frame. The Z-bit was set indicating that the local system considered the sequence number of the received frame incorrect (Nr count not valid).
- Processor Resource ....: &26
- Adapter Resource ......: &27
Message File : QCPFMSG
Library Message File : QSYS2924
BAL_S_LOG - Application Log: Log header data rdisp/max_wprun_time - Maximum work process run time
This documentation is copyright by IBM.
Length: 3252 Date: 20240427 Time: 033903 sap01-206 ( 3 ms )