CPI8FCA - Line &23 failed during insertion into the token-ring network. ( OS/400 )

CPI8FCA - Line &23 failed during insertion into the token-ring network. ( OS/400 )

TXBHW - Original Tax Base Amount in Local Currency   RFUMSV00 - Advance Return for Tax on Sales/Purchases  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8FCA
Line &23 failed during insertion into the token-ring network.

Message Long Text :

Cause . . . . . : The local area network adapter detected a duplicate node address (ADPTADR value in CRTLINTRN command) on the token-ring network during the insertion process into the network. The ADPTADR specified is already in use in the token-ring network.
Recovery . . . : Change the ADPTADR specified value in the CRTLINTRN command. To do this, vary off the line in error using the vary configuration (VRYCFG) command. Change the token-ring line description to specify a unique ADPTADR value using the CHGLINTRN command. Vary the line on again using the vary configuration (VRYCFG) command with the RESET(*YES) option. If the problem persists, press F14 to work with the problem.
Technical description . . . . . . . . : The local area network adapter card detected a failure during the insertion process into the token-ring network.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   Addresses (Business Address Services)  
This documentation is copyright by IBM.

Length: 3257 Date: 20240426 Time: 042843     sap01-206 ( 3 ms )