Internal distribution recipient index (*DRX) is being built again for user ID and address &1 &2.

Message Long Text :

Cause . . . . . : The *DRX for user ID and address &1 &2 was damaged and is being built again by the system. *DRX damage can occur if either the machine fails (machine check), or if the power is lost while an entry is being put on or taken off the index. Entries are put on the index when a distribution is sent. Entries are taken off the index when a user receives or cancels a distribution.
Recovery . . . : The system will do the build and loading in the job that sent this message. The job can be held (HLDJOB) until a later time or the running priority can be changed (CHGJOB) to cause less impact on the rest of the system. See the technical description for more information on holding the job.
Technical description . . . . . . . . : The job will be active for some time while the *DRX is being loaded. The job should not be canceled and should be allowed to complete building and loading the user's *DRX again. Holding jobs QDIA, QDIALOCAL, or QNFTP will stop office or network distributions from processing. Holding job QDIAINDUSR will stop printing for indirect users.
To bypass loading the *DRX for the user, you can end the job (ENDJOB) that is doing the build and then start the job again. If the job is running in the QSNADS subsystem, you will need to end the subsystem (ENDSBS) and then start the subsystem (STRSBS) again. If the job is ended, the distributions will not be loaded into the index again until an abnormal IPL occurs.