Ansicht
Dokumentation

CPIA972 - System value QIPLTYPE not set to 2. ( OS/400 )

CPIA972 - System value QIPLTYPE not set to 2. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPIA972
System value QIPLTYPE not set to 2.

Message Long Text :

Cause . . . . . : The system value for the type of initial-program-load (IPL) to perform (QIPLTYPE) is set to &1. This will cause problems with the Work with Hardware Products (WRKHDWPRD) option 5 after the upgrade to your AS/400 with PowerPC technology.
Recovery . . . : Do one of the following:
-- If you are using the Replacing-a-Release method to upgrade to an AS/400 with PowerPC technology, use the Change System Value (CHGSYSVAL) command just prior to the upgrade to change the value of QIPLTYPE to 2 (attended IPL with console in debug mode).
-- If you are using a method other than the Replacing-a-Release method, this value should be changed during the install of i5/OS on your AS/400 with PowerPC technology.
Technical description . . . . . . . . : The value for QIPLTYPE should only be changed immediately before the final power down to begin your upgrade. The value 2 for QIPLTYPE will put your console in debug mode and may affect normal system operation after the next IPL.

Message File : QCPFMSG
Library Message File : QSYS2924


Addresses (Business Address Services)   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.

Length: 3223 Date: 20240426 Time: 090759     sap01-206 ( 3 ms )