CPPC042 - *Attention* Deferred maintenance on I/O Adapter &27 is required. ( OS/400 )

CPPC042 - *Attention* Deferred maintenance on I/O Adapter &27 is required. ( OS/400 )

RFUMSV00 - Advance Return for Tax on Sales/Purchases   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPPC042
*Attention* Deferred maintenance on I/O Adapter &27 is required.

Message Long Text :

Cause . . . . . : The following caused the failure:
A memory error was detected on the adapter card.
Recovery . . . :
The card is still operational, so maintenance may be deferred. Report the problem to your hardware service provider for deferred maintenance.
Press F14 to report the problem.
Technical description . . . . . . . . : A portion of the adapter card storage is not usable. The I/O card Licensed Internal Code has changed the configuration of the adapter card storage. The failing adapter storage has been deallocated.

One or more memory modules (DIMMs) located on the adapter card was detected as being bad.

The failing DIMM is &36

If the failing DIMM is 'DIMM0_1' replace DIMM 0 or DIMM 1.
If the failing DIMM is 'DIMM2_3' replace DIMM 2 or DIMM 3.
If the failing DIMM is 'DIMMALL' replace all DIMMs.


.______________________________________.
: :
: :
:: DIMM 0 :
:: DIMM 1 :
:: DIMM 2 :
:: DIMM 3 :
: :
:____...............__............_____:
::::::::::::::: ::::::::::::

- Failing DIMM number ...: &36
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Problem Log ID ........: &35

Message File : QCPFMSG
Library Message File : QSYS2924


ABAP Short Reference   General Data in Customer Master  