Ansicht
Dokumentation
HTP8427 - Log file &1 is full, no additional logs will be saved. ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : HTP8427
Log file &1 is full, no additional logs will be saved.
Message Long Text :
Cause . . . . . : Log file &1 is completely filled. Any additional logs will not be saved.
The log files and their associated log sizes are specified on directives in the HTTP server configuration.
Recovery . . . : Do one of the following:
- Change the HTTP server configuration to specify a new log file.
- Change the HTTP server configuration to specify a larger maximum size for the log file.
- End the HTTP server instance and, if necessary, archive the log file that is full (&1). Then delete the log file.
Restart the HTTP server.
Message File : QHTTPMSG
Library Message File : QSYS2924
ABAP Short Reference PERFORM Short Reference
This documentation is copyright by IBM.
Length: 3247 Date: 20240426 Time: 081255 sap01-206 ( 3 ms )