Ansicht
Dokumentation
PQT2372 - The Encoding Scheme Identifier for the user data is not specified. ( OS/400 )
ROGBILLS - Synchronize billing plans BAL_S_LOG - Application Log: Log header dataThis documentation is copyright by IBM.
Message : PQT2372
The Encoding Scheme Identifier for the user data is not specified.
Message Long Text :
Cause . . . . . : An error was found while processing file &1 number &27 in job &5/&4/&3 created on system &37 at &38. The Encoding Scheme Identifier for User Data (ESidUD) is missing on the Encoding Scheme triplet (X'50') on a Begin Data Map (BDM) structured field. This information is required when processing an XML page definition. Processing of your print request has ended.
The error found with reason code &16. The reason codes have the following meanings:
1 -- Error in spooled file &1 number &27 for job &5/&4/&3 created on system &37 at &38.
2 -- Error in external resource &42 in library &13 of type &15.
3 -- Error in inline resource &42 of type &15.
Recovery . . . : You will need to provide the encoding scheme for the user data. Refer to Mixed Object Document Content Architecture Reference (SC31-6802) and AFP: Programming Guide and Line Data Reference (S544-3884) for information about the structured field. If the structured field has no error, the error might be a PSF logic error. If you used a program to create the structured fields for the page definition, contact your system programmer.
Technical description . . . . . . . . : The internal message identifier (ID) is &6.
Message File : QPQMSGF
Library Message File : QSYS2924
CL_GUI_FRONTEND_SERVICES - Frontend Services TXBHW - Original Tax Base Amount in Local Currency
This documentation is copyright by IBM.
Length: 3258 Date: 20240426 Time: 150025 sap01-206 ( 3 ms )