PQT4104 - Device &1 has a permanent hardware error. ( OS/400 )
ROGBILLS - Synchronize billing plans BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : PQT4104
Device &1 has a permanent hardware error.
Message Long Text :
Cause . . . . . : A permanent hardware error was detected for remote location &3, remote network &4, device &1, mode &5, local location &6, using ICF file &7 in library &8. The sense data received from the printer was &2. Processing by the printer writer ended.
Recovery . . . : Vary the APPC controller off and then on using the Work with Configuration Status (WRKCFGSTS) command. Then start the printer writer again. If the problem continues, report it using the ANZPRB command.
Message File : QPQMSGF
Library Message File : QSYS2924