Ansicht
Dokumentation
RNQ0402 - *PDA not valid for non-prestart job (C G D F). ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : RNQ0402
*PDA not valid for non-prestart job (C G D F).
Message Long Text :
Cause . . . . . : RPG procedure &1 in program &3/&2 attempted to access the PDA at statement &4 for a job that was not a prestart job. The PDA is valid only for prestart jobs.
Recovery . . . : Correct the data-area name in the *DTAARA DEFINE statement or run the program as a prestart job.
Possible choices for replying to message . . . . . . . . . . . . . . . :
D -- Obtain RPG formatted dump.
S -- Obtain system dump.
F -- Obtain full formatted dump.
C -- Cancel.
G -- Continue processing at *GETIN.
Message File : QRNXMSG
Library Message File : QSYS2924