Ansicht
Dokumentation

ISHMED_MAIN: Cycle - Enhancements (New) ( RELNISHMED604_MAIN_ME33 )

ISHMED_MAIN: Cycle - Enhancements (New) ( RELNISHMED604_MAIN_ME33 )

PERFORM Short Reference   BAL Application Log Documentation  
This documentation is copyright by SAP AG.
SAP E-Book

Short text

ISHMED_MAIN: Cycle - Enhancements (New)

Use

As of SAP ECC 6.0, Industry Extension Healthcare, Enhancement Package 4 (IS-H 604), Business Function Clinical System (ISHMED_MAIN), the cycle has been enhanced as follows:

  • Definition of day cycles
You can use these cycles in connection with the simplified dose definition.
For further information about the simplified dose unit, see the Release Note ISHMED_MAIN: Simplified Dose Definition (New)
  • Fixed interval
When cycles have a fixed interval (for example, every 8 hours), you can specify the start time (From Time field) of event generation by selecting the Define From Time checkbox. Event generation will take into account the cycle start time independently of the order start time.
  • Retroactive and future time interval in minutes
This enables you to stipulate that the system is to additionally generate a medication event at the order start if the retroactive time interval is fallen short of or if the future time interval is exceeded.
Examples
  • Retroactive time interval in minutes

The order starts at 08:15. The cycle defines the times 08:00, 12:00, and 16:00. Without a retroactive time interval, the first event would be generated at 12:00. You define a time interval of 30 minutes. The first event of the day could be generated at 08:00 (that is 15 minutes before the order start). The possible time interval of 30 minutes is fallen short of. As a result, an additional event is generated at the order start at 08:15.
This means that the system generates an additional event if the time of the first possible event was narrowly missed by the order start.
  • Future time interval in minutes

The order starts at 08:15. The cycle defines the times 08:00, 12:00, and 16:00. You define a time interval of 180 minutes. Since the first event is not generated until 225 minutes after the order start, the possible time interval of 180 minutes is exceeded. As a result, an additional event is generated at 08:15.
This means that the system generates an additional event if the time of the first event is too far from the order start.
The rules for retroactive and future are always used together. This means that the system creates at most one additional event at the order start. You can also generally determine minutes by means of the following organizational unit-related parameters (OU parameters):
  • N1ME_RETRO

  • N1ME_FWARD

Explicit specifications you make in the cycle will override these OU parameters.

Effects on Existing Data

Effects on Data Transfer

Effects on System Administration

Effects on Customizing

Further Information






ROGBILLS - Synchronize billing plans   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by SAP AG.

Length: 3603 Date: 20240520 Time: 191953     sap01-206 ( 59 ms )