Ansicht
Dokumentation

Changed Parameters in Release 4.72 (Changed) ( RELNISHMED_472_PARAM_001 )

Changed Parameters in Release 4.72 (Changed) ( RELNISHMED_472_PARAM_001 )

CPI1466 during Backup   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by SAP AG.
SAP E-Book

Short text

Changed Parameters in Release 4.72 (Changed)

Use

The following is a list of all parameters,

  • which are newly available in Release 4.72,
  • which are no longer used and
  • which have been replaced by others.

New parameter values and behavior of the corresponding programs are not included in this list. You should refer to the documentation on the individual parameters for more information on this.

System Parameters

NEW:

  • N1BPSTCT: Display Control for Employee Selection
This parameter can be used to format the employee selection for team entry separated into physician and nursing staff folders or in joint folders.
  • N2GCAREA: The reason is not applicable when canceling the steps of a patient pathway.
  • N2GPRREA: The reason is not applicable when canceling pathway-relevant steps of a patient pathway.

OU-Related Parameters

Via the basic clinical data of the hospital (menu path Clinical System -> Basic Clinical Data -> Service Management -> Organizational Unit -> OU-Related Settings -> Maintain) you can access the data screen to set up the OU-related parameters.

NEW:

This parameter is used to format the planning grid using display variants and determines the number of read attempts when searching for a replacement for days which are not displayed.
In the clinical order you can enter an anesthetist for order items of a surgery order type. You use this parameter to determine which organizational unit (OU) task should be used for the anesthetist.
In the clinical order you can enter an assistant for order items of a surgery order type. You use this parameter to determine which organizational unit (OU) task should be used for the assistant.
You use this parameter to determine for an organizational unit in the surgery area, at which time during surgical documentation the system should perform the checks, which can also be called using the "Check" function.
The checks can be set for the following times:
  • When the surgical documentation is released

  • When the surgical documentation is saved

  • Each time the ENTER key is clicked

NO LONGER SUPPORTED:

  • AU_ANF_ANL: Request Overview: Create Request
  • DOK_POPUP: Worklist, Waiting List: Create Document - Management Data
  • LEAVE_WIDB: Follow-Up Visit: Create Visit/Appointment - Additional Data
  • N1ANFO_IB: Worklist: Lock Request for Requester
  • N1ANFWPDT: Request, Preregistration: Replace Appointment with Desired Time
  • N1IMA_OE: Clinical Work Station: Check Employee in Team Entry
  • N1KPELB: Day-Based Planning: Width of Worklist
  • N1MARKAL: Worklist: Selection Control
  • N1MARKML: Medical Unit List: Selection Control
  • N1MARKWR: Waiting List: Selection Control
  • N1OECOL: Medical Unit List: Colored Highlighting of Companion
  • N1PALMPCD: Nursing: Function for Downloading Companion
  • N1TMEBSRC: Appointment Management: Activate Appointment Search for Initial Visit
  • N1TMPLSRC: Appointment Management: Activate Appointment Search for Plan Appointment
  • N1TMWBSRC: Appointment Management: Activate Appointment Search for Follow-Up Visit
  • N1VKLOE: Preregistration List Without Variant: OU When Calling from Worklists
  • N1VPBILB1: Vital Signs: Time - Start of First Balancing Period
  • N1VPBILB2: Vital Signs: Time - Start of Second Balancing Period
  • N1VPBILD1: Vital Signs: Period to Be Balanced (Period 1)
  • N1VPBILD2: Vital Signs: Period to Be Balanced (Period 2)

REPLACED

  • N1WP_ANFHS: Clinical Work Station: Request Exists Hotspot
You should use system parameter N1WP_AHS instead.
  • N1WP_DOKHS: Clinical Work Station: Document Exists Hotspot
You should use system parameter N1WP_DHS instead.
  • OP_BEW_ART: Surgery: Determine Surgery Movement Type
You should use OU parameter OE_BEW_ART instead.

User Parameters

NEW:

  • N1PT_VIS_COMMENT: Planning Grid: Show Daily Comments
  • N1PT_COMMENT_HEIGHT: Planning Grid: Height of Daily Comments Area
  • N1PT_INF_DV_FV: Planning Grid: Display Variant for Follow-Up Visit
  • N1PT_INF_DV_IV: Planning Grid: Display Variant for Initial Visit
  • N1PT_INF_DV_NM: Planning Grid: Display Variant for Planning
  • N2_RAD_DWS_START: Findings Work Station: Start Variant
  • N2_RAD_PERF_PHYS: Findings Work Station: Examining Radiologist
  • N2_RAD_PACSID: Findings Work Station: PACS-RIS Study Assignment
  • N2_RAD_DETAILREFRESH: Findings Work Station: Automatically Refresh Detail View
  • N1VKGTPA: Clinical Order: Display Selection List for Order Types
If you do not enter the user parameter, the system will use the existing system parameter of the same name N1VKGTPA.

NO LONGER SUPPORTED

  • N2_RAD_ALV: IS-H*MED RAD Worklist as ALV
Instead you configure the display of the findings work station worklist in the selection screen or in the program variants of the work station using the selection parameter Worklist as List.

System Parameters

NEW:

You use this parameter to define which time the system should use to calculate the waiting time in the Outpatient Clinic/Service Facility view type of the clinical work station.
  • '1' = Creation time of visit (standard value)

  • '2' = Visit time

You use this parameter to determine whether the system should use the normal document display or the print preview when Get Data is executed in the document.

Effects on Existing Data

Effects on Data Transfer

Effects on System Administration

Effects on Customizing

Further Information






rdisp/max_wprun_time - Maximum work process run time   Vendor Master (General Section)  
This documentation is copyright by SAP AG.

Length: 9251 Date: 20240602 Time: 163421     sap01-206 ( 58 ms )