SIMG_LEDCC - Define Storage Type Settings

SIMG_LEDCC - Define Storage Type Settings

BAL_S_LOG - Application Log: Log header data   RFUMSV00 - Advance Return for Tax on Sales/Purchases  
This documentation is copyright by SAP AG.
SAP E-Book

In this IMG activity, you define, for different storage types, settings for dynamic cycle counting.

If you want to work with dynamic cycle counting (i.e counting against inactive inventory documents) in a specific storage type, you must create at least one record in this activity.

For each storage type for which you want to implement dynamic cycle counting, do the following:

  1. In the Warehouse field, enter the warehouse number.
  2. In the Storage Type field, enter the storage type identifier.
  3. If you want the system to block the creation of further transfer orders for a bin after it has found differences during a dynamic cycle count, select BlockTO.
  4. If you want the system to activate inventory documents immediately at confirmation of the last transfer order of a bin (i.e when there are no more open TOs for the bin), after it has found differences during a dynamic cycle count, select Immed.
  5. From the AutoCl drop-down list, choose an option for automatic clearing of inventory documents in WM.
  6. If you want to cause inventory documents created for counting by material to be inactive, select ByQuant.






CL_GUI_FRONTEND_SERVICES - Frontend Services   Addresses (Business Address Services)  
This documentation is copyright by SAP AG.