Ansicht
Dokumentation

_ISUBISFGA_000040 - Gas-Relevant Data in Register

_ISUBISFGA_000040 - Gas-Relevant Data in Register

ROGBILLS - Synchronize billing plans   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by SAP AG.
SAP E-Book

You can maintain the following gas-relevant fields at register level.

  • Enter a key in the following fields, under which you can store fixed values:

  • The following values decide on the gas procedure that is permissible for installing a register in an installation:
  • Thermal gas billing

  • Nominal load

  • Measured pressure

The following are at installation level:
  • Rate category

  • Type of gas billing

  • Billing class

Enter the gas procedure for the device installation at register level, in the GasP field. The gas procedure valid for a register is determined as follows:

The billing class and the type of gas billing are determined from the current rate category allocated to the installation. All gas procedures (with this billing class and type of gas billing) that are marked as inactive, are copied to a preselection.

Then the system checks the volume correction factor procedure for the respective gas procedure, to see whether the nominal load and the measured pressure of the device/register are also in the areas defined for the nominal load or measured pressure. The same factors must be taken into account for thermal gas billing in both the volume correction factor procedure and in the register.

Only a gas procedure that corresponds to all requirements is a permissible gas procedure.

You can maintain the following gas-relevant fields directly for the installation of a gas meter:

  • Measured pressure
  • Gas procedure
  • Temperature area
  • Gas pressure area
  • Air pressure area
  • Calorific value district
  • Altitude correction pressure
  • Gas correction pressure
  • Actual gas law deviation factor
  • Set gas law deviation factor
  • Volume correction factor from register

To add historical changes, choose the following in the SAP Menu:

  • Device Management -> Installation -> Installation Structure -> Device Allocations -> Maintain, to change the following fields:
  • Measured pressure

  • Allocation of pressure regulator

  • Device Management -> Installation -> Modification, to change the following fields:
  • Temperature area

  • Air pressure area

  • Gas pressure area

  • Calorific value district

  • Altitude correction pressure

  • Gas correction pressure

  • Set or actual gas law deviation factor

  • Device Management -> Installation -> Installation Structure -> Rate Data -> Change, to change the following fields:
  • Gas procedure

  • Fixed temperature key

  • Volume correction factor from register






Addresses (Business Address Services)   Addresses (Business Address Services)  