Ansicht
Dokumentation
CPA4058 - Volume &5 on device &4 wrong type (C INZ R). ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time Fill RESBD Structure from EBP Component StructureThis documentation is copyright by IBM.
Message : CPA4058
Volume &5 on device &4 wrong type (C INZ R).
Message Long Text :
Cause . . . . . : Volume &5 on device &4 is the wrong type for &7 file &2 in &3. A standard label volume is required for a *SL or *BLP file. A nonlabeled volume is required for a *NL, *NS, or *LTM file.
Recovery . . . : Do one of the following:
-- Use C to cancel processing.
-- Use INZ to initialize the current volume to the correct format.
-- Put the correct type volume &6 on the tape drive, and use R to try the operation again.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel processing
R -- Try the volume open operation again
INZ -- Initialize the current volume
Message File : QCPFMSG
Library Message File : QSYS2924
ABAP Short Reference General Data in Customer Master
This documentation is copyright by IBM.